Introduction
Successful implant therapy extends beyond achieving osseointegration. The long-term preservation of healthy peri-implant tissues depends on restorative designs that respect the biology of the surrounding hard and soft tissues while allowing effective plaque control and long-term maintenance (Fabbri, Mintrone et al. 2025, Wang, Avila‐Ortiz et al. 2025). While considerable attention has traditionally been directed towards implant placement and osseointegration, the restorative phase is equally important in establishing and maintaining a stable peri-implant environment. Restorative design influences the dimensions and integrity of the peri-implant soft tissue seal, the emergence profile, plaque accumulation, cleansability, and the ability to monitor and maintain peri-implant tissues over time (Chen, Monje et al. 2026, Monje, Jung et al. 2026). Consequently, many biological complications associated with implant therapy may be influenced, at least in part, by restorative design and prosthetic decision-making (Chen, Monje et al. 2026). This article discusses the restorative factors that influence peri-implant health and summarizes the current evidence supporting biologically driven prosthetic design.
Understanding the Prosthetic-Biologic Interface
Successful implant function depends on two complementary biological processes: osseointegration, which provides a direct structural and functional connection between bone and the implant surface, and peri-implant soft tissue integration, which establishes a mucosal barrier around the transmucosal component. This barrier protects the underlying crestal bone from the oral environment and is therefore essential for maintaining peri-implant health (Berglundh, Lindhe et al. 1991, Klinge and Meyle 2006).
Unlike gingiva, which develops during tooth eruption, peri-implant mucosa forms through wound healing following implant placement. It lacks a periodontal ligament, has a comparatively reduced vascular supply, and contains connective tissue fibers that run predominantly parallel or circumferential to the implant surface rather than inserting into it. These structural characteristics may make the peri-implant mucosa less resistant to inflammatory and mechanical challenges (Salvi, Bosshardt et al. 2015). The peri-implant soft tissue phenotype includes keratinized mucosa width, mucosal thickness, and supracrestal tissue height (Avila‐Ortiz, Gonzalez‐Martin et al. 2020, Mattheos, Vergoullis et al. 2021). Internally, the peri-implant mucosa comprises the peri-implant sulcular epithelium (PISE), peri-implant junctional epithelium (PIJE), and peri-implant connective tissue (PICT). The PIJE adheres to the implant or abutment surface through hemidesmosomes and an internal basal lamina, whereas the PICT forms a close connective tissue adhesion without true fiber insertion (Atsuta, Ayukawa et al. 2016, Avila‐Ortiz, Gonzalez‐Martin et al. 2020, Mattheos, Vergoullis et al. 2021) (Figure 1).
These tissues coexist with the transmucosal implant, abutment, and prosthetic components and the surrounding biofilm as part of the implant supracrestal complex. This concept recognizes the peri-implant tissues, restorative components, and oral biofilm as an integrated anatomical and functional system rather than describing the interface solely as a supracrestal tissue attachment (Mattheos, Vergoullis et al. 2021). Preserving the dimensions and integrity of this complex is fundamental to restorative therapy because emergence profile, component position, and prosthetic design can influence the stability of the peri-implant tissue barrier and the underlying crestal bone.

Fig. 1: Comparison of the supracrestal tissues around a natural tooth and a dental implant. Around the tooth, connective tissue fibers insert into the cementum, whereas around the implant, the peri-implant junctional epithelium adheres to the abutment surface, and the connective tissue fibers run predominantly parallel or circumferential without inserting into it. The approximate dimensions of the epithelial and connective tissue compartments are illustrated
Emergence Profile: The Foundation of Soft Tissue Stability
The emergence profile (EP) refers to the contour of the implant-supported restoration as it transitions from the implant platform to the definitive prosthetic crown (Mattheos, Vergoullis et al. 2021, Pelekos, Chin et al. 2023, Pedrinaci, Hamilton et al. 2024). Emergence profile design is determined largely by three-dimensional implant position and the available peri-implant tissue volume. A prosthetically driven implant position provides the restorative space required to develop a gradual transmucosal contour while preserving adequate tissue dimensions and access for oral hygiene (Siegenthaler, Strauss et al. 2022, Esquivel, Meda et al. 2026, Pirc, Balzarini et al. 2026) Emergence profiles are commonly classified as concave, straight, or convex (Figure 2). A concave profile curves inward as it extends coronally from the implant platform, thereby preserving space for the peri-implant tissues. A straight profile provides a relatively uniform transition, whereas a convex profile projects outward and occupies a greater proportion of the transmucosal space. Convexity may be required in selected situations to support the mucosal margin or compensate for implant position (Steigmann and Monje 2014) but excessive convexity may compress the peri-implant tissues and create areas that are difficult to clean. A recent RCT found that single implants restored with convex emergence profiles had a higher risk and frequency of midfacial mucosal recession than those with concave profiles. This difference was observed at 12 months and remained at 3-year follow-up (Siegenthaler, Strauss et al. 2022, Endres, Strauss et al. 2025). A cross-sectional study has also associated wider emergence angles with increased plaque accumulation and peri-implant inflammation, while wider prosthetic contours have been associated with reduced peri-implant mucosal dimensions (Pelekos, Chin et al. 2023, Rungtanakiat, Thitaphanich et al. 2024). These findings support the use of a controlled, generally concave transmucosal contour when anatomically and prosthetically feasible, particularly in the apical portion of the emergence profile. Nevertheless, the final contour should be determined according to implant position, tissue phenotype, restorative material requirements, and the intended esthetic outcome rather than applying a uniform profile to all clinical situations.

Fig. 2: Schematic representation of different implant restoration emergence profiles.
The Esthetic Biological Contour (EBC) concept provides a clinical framework for relating different portions of the emergence profile to the adjacent peri-implant tissues (Esquivel, Meda et al. 2026). It divides the submucosal restoration into the E-zone, B-zone, and C-zone, each of which has distinct esthetic, restorative, and biological considerations (Figure 3). The E-zone comprises the most coronal 0.5–1 mm of the submucosal restoration and primarily influences the position and support of the mucosal margin. Minor additions or reductions in restorative volume within this zone may alter the apicocoronal position of the margin. The response, however, depends on the facial tissue phenotype and the underlying tissue support. Adequate facial tissue thickness is therefore required before attempting substantial contour modification in this region, particularly in the esthetic zone (Esquivel, Meda et al. 2026).
Immediately apical to the E-zone, the B-zone corresponds to the restorative room and lies adjacent to the peri-implant junctional epithelium. This region accommodates the progressive transition from the narrower transmucosal component to the cervical contour of the crown. Its morphology should provide appropriate mucosal support without excessive compression or abrupt expansion. Repeated manipulation of transmucosal components and excessive restorative convexity may interfere with the stability of the epithelial interface. A smooth and moderately concave contour may preserve the space available for the epithelial compartment while allowing a gradual transition towards the mucosal margin. The vertical dimension and degree of contouring required in this zone vary according to implant depth, anatomical location, tissue phenotype, and esthetic requirements. Excessive buccal convexity should be avoided because it may create tissue tension and encroach upon the peri-implant supracrestal tissues (Fabbri, Mintrone et al. 2025, Esquivel, Meda et al. 2026).
The C-zone, or biological room, extends coronally from the implant platform or first bone-to-implant contact to the B-zone and corresponds predominantly to the peri-implant connective tissue compartment. Its vertical dimension is influenced by implant depth, implant and abutment design, and the available soft tissue phenotype. Because this region is situated immediately coronal to the crestal bone, excessive prosthetic flare may reduce the space available for connective tissue integration and contribute to crestal bone remodeling. A straight or slightly concave contour within the apical 1–2 mm of the transmucosal component has therefore been proposed to preserve the connective tissue compartment and provide a gradual transition towards the restorative room (Esquivel, Meda et al. 2026).

Fig. 3: The EBC zones of the peri-implant emergence profile. 
Fig. 4a: Functional, morphological, and material characteristics of the E-zone, B-zone, and C-zone of the peri-implant emergence profile
Determinants of Emergence Profile Design
Implant depth is a key determinant of emergence profile design (Pirc, Esquivel et al. 2026). Shallow implants may force the prosthetic contour to flare too close to the crestal bone (Misch, Abu‐Reyal et al. 2025) while excessively deep implants create a long mucosal tunnel that may increase plaque accumulation and delay resolution of inflammation (Chan, Pelekos et al. 2019, Pelekos, Chin et al. 2023). While implant depth must be planned to balance esthetic emergence, biological space, and cleansability, the optimal depth from a biological perspective remains unclear. Abutment selection is also important: short stock abutments may place the restorative margin too deep, whereas taller titanium bases can relocate the prosthetic interface coronally and better preserve the soft-tissue seal (Strauss, Park et al. 2024, Esquivel, Meda et al. 2026).
The mesio-distal implant position influences the interproximal emergence profile and papillary support. Implants placed too mesially or distally may flatten the emergence contour on one side, reducing the space available for prosthetic material and soft tissue volume. This can compromise papilla formation and may contribute to crestal bone remodeling (Esquivel, Meda et al. 2026).
The buccal position is equally critical. Buccally positioned implants limit the space for facial bone, soft tissue thickness, and restorative material, often forcing a flat or convex emergence profile to compensate for the lack of restorative space. This may increase the risk of facial recession, esthetic compromise, and buccal bone dehiscence (Buser, Martin et al. 2004, Lin, Chan et al. 2014, Martin, Pollini et al. 2014, Sanz‐Martín, Regidor et al. 2020). In contrast, a prosthetically driven implant position allows the clinician to develop a more favorable concave transmucosal contour (Chu, Kan et al. 2019, Esquivel, Meda et al. 2021, Gomez‐Meda, Esquivel et al. 2021).
Axial inclination also affects emergence profile geometry. Although angulated screw channels and dynamic screws can compensate for prosthetic access, they do not eliminate the biological consequences of poor implant angulation. Excessive facial inclination may place the implant neck outside the ideal restorative envelope, reduce facial tissue thickness, and require a wider or flatter emergence profile. In cases requiring major angle correction, the screw channel may become larger and shift apically, bringing the restorative flare closer to the bone crest (Figure 4b). Custom abutments may help reduce the bulk of the C-zone, but only within the limits of minor implant malposition (Esquivel, Meda et al. 2026).

Fig. 4b. Influence of implant position on the restorative emergence contour. (A) Ideal 3D position, (B) shallow placement, (C) palatal placement, (D) buccal placement, (E) facial angulation, and (F) mesiodistal offset. Turquoise outlines highlight the associated changes in the transmucosal restorative contour (Adapted from Esquivel et al. 2021)
Contour and Cleansability
Long-term peri-implant health depends on both a stable biological seal and effective biofilm control. Restorative contours should therefore facilitate daily oral hygiene and professional maintenance without compromising the peri-implant soft tissue interface (Pelekos, Chin et al. 2023).
Within the transmucosal restoration, the restorative room (RR) remains accessible for oral hygiene and professional maintenance, whereas the biological room (BR) cannot be predictably instrumented because of its apical position and close relationship with the implant–abutment complex. Mechanical instrumentation within the BR may disrupt epithelial adhesion and compromise the biological seal. Prevention of biofilm accumulation through appropriate prosthetic design is therefore preferable to mechanical decontamination after disease has developed (Fabbri, Mintrone et al. 2025).
Over-contoured restorations, excessive cervical convexity, steep emergence profiles, and wide restorative angles create plaque-retentive areas that are difficult for patients to access and may also restrict professional instrumentation (Pelekos, Chin et al. 2023).

Fig. 5: Relationship between restorative emergence angle, inflammatory infiltrate, and first bone-to-implant contact (fBIC). (a) A narrow restorative emergence angle showing limited biofilm accumulation, an inflammatory infiltrate confined coronally, and a greater distance between its apical termination and the fBIC, with the crestal bone maintained at the implant–abutment junction. (b) A wide emergence angle is associated with increased biofilm accumulation, apical extension of the inflammatory infiltrate, and a shorter distance to fBIC, accompanied by marginal bone loss. Yellow arrows indicate the distance between the apical extent of the inflammatory infiltrate and fBIC, marked by purple circles. The illustration is based on the findings of Strauss, Park et al. 2024.
Interproximal contours should support the papilla without excessively narrowing the embrasure spaces. Excessive convexity restricts access for floss and interdental brushes, limiting cleaning efficacy (Sirinirund, Siqueira et al. 2023), whereas excessively open embrasures may compromise papillary support and esthetics. Adequate access for interdental cleaning is particularly important in patients with reduced dexterity or a history of periodontal or peri-implant disease.
Surface characteristics also influence plaque accumulation. The E-zone is continuously exposed to the oral environment and should have a highly polished surface to reduce bacterial adhesion and facilitate plaque removal. Rough, glazed, or over-contoured transmucosal surfaces should be avoided. When veneering ceramics, stains, or glazing are required, their application should be confined to the supragingival esthetic interface, while the subgingival transmucosal surface should remain highly polished (Esquivel, Meda et al. 2026).
Abutment Design and Soft Tissue Response
Transmucosal abutment geometry encompasses the height, diameter, contour, and emergence angle of the component extending from the implant platform to the prosthetic restoration. These features determine the space available for the peri-implant tissues and the cleansability of the restoration. Abutment selection should therefore be incorporated into restorative planning rather than regarded as a purely mechanical decision.
The emergence angle describes the angle at which the abutment or restoration diverges from the implant axis. It should be assessed at both the abutment and crown levels because the contour of the definitive restoration may differ from that of the transmucosal abutment. Long-term cross-sectional evidence has further associated wider crown emergence angles with peri-implant disease, with thresholds above 40° for bone-level implants and 48° for tissue-level implants. (Strauss, Siegenthaler et al. 2022, Rungtanakiat, Thitaphanich et al. 2023, Raabe, Fonseca et al. 2026, Strauss, Monje et al. 2026) (Figure 6).

Fig. 6: Influence of restorative emergence angle on peri-implant soft tissue inflammation and marginal bone stability. Adapted from Strauss, Park et al. 2024
Abutment contour may also influence the peri-implant tissue response. An experimental human study comparing different abutment macro- and microgeometries found that a convergent profile with an ultrathin threaded surface was associated with a greater vertical connective tissue dimension and a higher density of collagen bundles than a divergent profile (Canullo, Giuliani et al. 2023). Clinical evidence also indicates that contour influences marginal soft tissue stability. A randomized clinical trial and its 3-year follow-up found midfacial recession more frequently with convex than concave profiles, with most changes occurring during the first year (Siegenthaler, Strauss et al. 2022, Endres, Strauss et al. 2025). A meta-analysis of four randomized trials showed the same direction of effect, although the pooled difference did not reach statistical significance (Pirc, Balzarini et al. 2026).
Abutment diameter should be considered alongside its contour. In a randomized study of 64 implants, cylindrical abutments were associated with less crestal bone remodeling and bleeding on probing than wider abutments during the first year of loading (Bernabeu‐Mira, Peñarrocha‐Diago et al. 2023). Excessive transmucosal bulk should therefore be avoided when it places pressure on the peri-implant tissues or restricts access for plaque control.
The response to abutment design is also influenced by the soft tissue phenotype. In a split-mouth randomized study, vertical soft tissue thickness and keratinized mucosa width of less than 2 mm were associated with greater marginal bone loss over 12 months. No significant difference was found between platform-matched and platform-switched restorations, while the soft tissue phenotype showed a greater influence on marginal bone loss (Chanh, Thanh et al. 2025). Although an earlier systematic review and meta-analysis reported less marginal bone-level change with platform switching than with platform-matched configurations, platform switching should not be considered a substitute for adequate tissue dimensions, appropriate implant positioning, and a cleansable restoration (Strietzel, Neumann et al. 2015).
Abutment height should be selected according to the available vertical soft tissue thickness. Transmucosal abutments of at least 2 mm have been associated with reduced marginal bone loss, possibly by providing sufficient vertical space for the peri-implant supracrestal tissues. Conversely, short abutments may position the restorative interface too close to the crestal bone and contribute to marginal bone remodeling. In sites with limited vertical tissue thickness, subcrestal implant placement combined with a longer transmucosal abutment may provide a more favorable restorative and biological relationship. Abutment height should therefore be selected according to the tissue dimensions of the individual site rather than applying a uniform approach (Spinato, Stacchi et al. 2020, Munoz, Vilarrasa et al. 2023).
Screw versus Cement-Retained Restorations
The choice between screw-retained and cement-retained implant-supported restorations has implications for biological complications, technical complications, and long-term maintenance. A systematic review reported high estimated 5-year survival with both approaches. Survival differences between cement-retained and screw-retained single crowns (96.5% versus 89.3%), partial fixed dental prostheses (96.9% versus 98.0%), and full-arch prostheses (100% versus 95.8%) were not statistically significant (Sailer, Mühlemann et al. 2012). Retention should therefore be selected primarily according to the anticipated complication and maintenance profile rather than survival alone.
Long-term evidence is provided by a randomized clinical trial of 44 esthetic-zone single implants restored with either a screw-retained veneered one-piece zirconia abutment or a lithium disilicate crown cemented onto a one-piece zirconia abutment. At 7.5 years, 31 patients attended the final examination. Restoration survival was 81.0% with screw retention and 74.0% with cement retention, with no significant intergroup difference. Marginal bone-level changes were also comparable. However, bleeding on probing was lower with screw-retained restorations (20 ± 17% versus 40 ± 22%; p = .011), and cement-retained restorations had a higher total complication rate (84.2% versus 38.1%; p = .0041). Biological and technical complication rates considered separately did not differ significantly (Kraus, Hjerppe et al. 2024). These findings favor screw retention from a maintenance perspective but require cautious interpretation. The high abutment-fracture rate and low restoration survival may have been influenced by the one-piece zirconia abutment connection and the inclusion of premolar sites, limiting generalizability to other materials and connection designs.
Evidence regarding marginal bone levels remains inconsistent. An analysis of prospective multicenter studies found slightly less marginal bone loss with cemented restorations at 3 and 5 years, although the differences were considered clinically negligible and peri-implantitis prevalence was comparable between retention types (Strauss, Hämmerle et al. 2021). Retention type alone should therefore not be regarded as an independent determinant of marginal bone stability.
Screw-retained restorations eliminate residual cement and permit retrieval during maintenance, repair, or treatment of peri-implant disease. They are particularly useful when repeated removal is anticipated, including provisional restorations used for soft tissue conditioning and long-span or cantilever prostheses. Their use requires prosthetically driven implant placement to obtain a favorable access-channel position. Disadvantages include possible esthetic or occlusal compromise and technical complications such as screw loosening or ceramic chipping (Wittneben, Millen et al. 2014, Millen, Brägger et al. 2015, Hamed, Abdullah Mously et al. 2020).
The principal biological concern with cement-retained restorations is residual cement, which may retain plaque and promote peri-implant inflammation, particularly when the restorative margin is located deeply below the mucosal margin. Detection is difficult, and cement remnants were radiographically visible in only 7.5% of mesial and 11.3% of distal sites, indicating that a negative radiograph does not confirm complete removal (Linkevicius, Puisys et al. 2013). Furthermore, the longer residual cement remains around an implant, the greater the associated inflammation, suppuration, and peri-implant tissue destruction, underscoring the importance of complete cement removal (Kraus, Hjerppe et al. 2024).
Cement-retained restorations remain useful when implant angulation produces an unfavorable screw-access position or when the access channel would compromise crown morphology. When cement retention is selected, the restorative margin should be positioned as coronally as clinically feasible, cement should be applied sparingly, and excess material should be removed immediately. Extraoral pre-seating on an abutment analog may further reduce cement extrusion. Postoperative radiographs may assist in detecting radiopaque remnants but should not be the sole method of verification. Retention should ultimately be selected according to implant position, prosthesis design, retrievability, esthetic requirements, and the anticipated biological and technical maintenance burden.
Prosthetic Materials and Peri-Implant Soft Tissue Health
The material used for implant abutments influences the biological response of the peri-implant soft tissues through its biocompatibility, surface characteristics and susceptibility to plaque accumulation. Titanium and zirconia remain the most widely used abutment materials because of their favorable biological and mechanical properties. Current evidence, however, does not support selecting one material over another solely to improve peri-implant soft tissue stability. A systematic review found no meaningful differences in marginal bone level, probing depth, biological complications or esthetic outcomes between titanium and zirconia abutments over medium-term follow-up (Laleman, Lambert et al. 2023). Similarly, a controlled clinical study reported comparable clinical, microbiological, molecular, and histological soft tissue responses around titanium, zirconia, feldspar-veneered zirconia, and PEEK healing abutments (Enkling, Marder et al. 2022). Experimental and clinical studies have nevertheless reported reduced plaque accumulation and a more apically positioned biofilm around zirconia than titanium, although these differences have not consistently translated into superior clinical outcomes (van Brakel, Cune et al. 2011, Bittencourt, Assis et al. 2023). Monolithic zirconia restorations have also demonstrated clinical performance comparable to porcelain-fused-to-metal restorations for single implant crowns in the posterior region, supporting their use where both esthetics and biological compatibility are desired (Mühlemann, Lakha et al. 2020). Consequently, material selection should be guided primarily by the restorative indication, esthetic requirements, and mechanical demands of the individual case. Titanium abutments remain the material of choice where maximum mechanical strength is required, whereas zirconia may be advantageous in the esthetic zone because of its tooth-colored appearance (Halim, Pesce et al. 2022). Facial mucosal thickness should also be considered when selecting the abutment material. A thickness of at least 2 mm is generally sufficient to mask the color of the underlying component, whereas thinner tissues are more susceptible to visible discoloration and may favor the use of tooth-colored materials (Bienz, Pirc et al. 2022)
The Role of Provisional Restorations
Provisional restorations are more than temporary prostheses; they provide an important opportunity to shape and stabilize the peri-implant soft tissues before fabrication of the definitive restoration (Bichacho and Landsberg 1997, Wittneben, Buser et al. 2013, Papadopoulos, Pozidi et al. 2014, Siegenthaler, Strauss et al. 2022). Immediate provisionalization has therefore been advocated, particularly in the esthetic zone, as it provides a stable scaffold for soft tissue maturation while maintaining patient comfort and avoiding the need for a removable interim prosthesis (González-Martín, Lee et al. 2020). The contour of the provisional restoration plays a central role in tissue conditioning (Meng, Chien et al. 2021). Customized cervical contours and concave transmucosal profiles have been recommended to guide soft tissue adaptation, minimize facial recession, and facilitate development of a natural emergence profile. Progressive modification of the provisional restoration can further sculpt the peri-implant mucosa and support papilla maturation by applying controlled pressure to selected areas while avoiding excessive compression of the tissues (Su, González-Martín et al. 2010). Following osseointegration, the peri-implant soft tissues should be reassessed before fabrication of the definitive restoration (Esquivel, Meda et al. 2026). Minor deficiencies in tissue contour may often be corrected through incremental modification of the provisional restoration, whereas more pronounced deficiencies generally require surgical augmentation before fabrication of the definitive prosthesis. At immediate implant sites, this conditioning process may begin on the day of surgery, as immediate provisionalization provides early tissue support and, in intact extraction sockets, has been associated with 0.87 mm less apical migration of the midfacial mucosa than immediate placement without provisionalization, although the certainty of evidence remains low (Pitman, Seyssens et al. 2022). Once stable peri-implant tissue contours have been established, the definitive restoration should accurately reproduce the emergence profile and transmucosal contours developed by the provisional restoration to preserve the soft tissue architecture achieved during conditioning.
Maintenance Begins at the Restorative Stage
Supportive peri-implant care should be incorporated into restorative planning rather than initiated only after biological complications develop. The definitive restoration should permit effective self-performed plaque control and provide sufficient access for clinical examination and professional instrumentation. The EFP S3-level clinical practice guideline recommends regular supportive peri-implant care for patients with healthy peri-implant tissues, together with individually tailored oral-hygiene instructions and reinforcement of adherence to both home care and maintenance visits (Herrera, Berglundh et al. 2023). Following completion of active treatment, the maintenance program should be adapted to the individual risk profile, considering periodontal status, plaque control, smoking, glycemic control, peri-implant tissue conditions, and prosthetic accessibility. The recent AO/AAP consensus similarly emphasizes early recognition and control of modifiable risk factors together with personalized supportive maintenance as essential components of long-term peri-implant care (Kumar, Kan et al. 2025, Wang, Avila‐Ortiz et al. 2025). Because risk may change over time, recall intervals should be periodically reassessed rather than applied uniformly throughout follow-up.
Longitudinal monitoring requires comparison with previously recorded peri-implant conditions. The EFP guideline recommends peri-implant probing to assess bleeding on probing and to identify changes in probing depth and mucosal margin level (Herrera, Berglundh et al. 2023). These findings should be interpreted together with plaque accumulation, suppuration and changes in the peri-implant soft tissues, while radiographic assessment should be undertaken when clinically indicated to evaluate changes in marginal bone levels. Early crestal bone loss or alterations in peri-implant soft-tissue conditions warrant reassessment of contributing factors and closer surveillance. When such changes are identified, shortening the recall interval and considering corrective intervention may be appropriate (Berglundh, Armitage et al. 2018, Chen, Monje et al. 2026).
The prosthesis should also be reassessed as part of supportive care. Changes in tissue morphology or limitations inherent to the prosthetic design may impair self-performed plaque control or restrict professional access even when the restoration was initially acceptable. Where cleansability is compromised, modification of the prosthesis should be considered whenever feasible. In selected inaccessible or full-arch reconstructions, periodic removal may be required to permit adequate examination of the peri-implant tissues and delivery of supportive peri-implant care (Lanzetti, Crupi et al. 2024, Chen, Monje et al. 2026). Maintenance therefore represents active longitudinal surveillance in which preventive measures, recall frequency, and professional access are adapted to changes in biological risk and peri-implant tissue conditions over time.
Clinical Takeaways
| Clinical consideration | Favors peri-implant health | Less favorable |
| Emergence profile | Concave or straight transmucosal profile | Over-contoured convex profile |
| Emergence angle | ≤40º (bone-level) / ≤48° (tissue-level) | Greater emergence angles |
| Restorative contour | Progressive, cleansable contour | Excessive cervical convexity |
| Restorative surface | Highly polished transmucosal surface | Rough or glazed subgingival surface |
| Implant position | Prosthetically driven implant position | Buccal, shallow positioning or excessively deep |
| Screw vs cement retention | Screw-retained where retrievability or peri-implant maintenance is important | Cement-retained restorations without meticulous cement control |
| Residual cement | Complete cement removal | Deep residual cement |
| Abutment contour | Concave or convergent profile | Broad or excessively convex profile |
| Abutment diameter | Narrow/cylindrical where appropriate | Wide transmucosal profile |
| Abutment height | ≥2 mm when soft tissue thickness permits | Short abutments in thin mucosa |
| Implant–abutment configuration | Platform-switched configuration | Platform-matched configuration |
| Provisional restoration | Customized provisional for tissue conditioning and emergence profile development | Immediate definitive contour without tissue conditioning |
| Maintenance | Restorations designed for plaque control and professional access | Designs that impede hygiene and monitoring |
Conclusion
Restorative decisions can influence peri-implant tissue stability throughout the lifespan of an implant. Prosthetically driven implant positioning, controlled transmucosal contours, appropriate abutment and retention selection, and a restoration that remains cleansable and monitorable should therefore be considered integral components of peri-implant disease prevention.